The Lynx II for Microscopy and Histology comes with everything found in both units.Not to be confused with the delicate pyrolytic graphite sheet (PGS) or graphene composite or sheet materials advertised elsewhere as being extremely fragile and prone to failure, Thermal LyNX ® is both robust enough to meet any demanding application while at the same time having far superior thermal performance and orders of magnitude higher flexibility than any other carbon or graphite fiber thermal strap. The Lynx II for Histology comes with: Histo Sample Holder, Histo Sample Arm, Histo Carousel, Power Cord, Operator Manual, Histo Aluminum Containers (12), Histo Plastic Containers (36), Plastic Caps (36), Exhaust Hose, Small Cassettes (100), 2 Sample Record Note Pads, Spare Fuses. The Lynx II for Electron Microscopy comes with: EM Sample Holder, EM Sample Arm, EM Carousel, Loading Jig, Power Cord, Operator Manual, Aluminum Containers (24), Plastic Containers (72), Plastic Caps (72), Exhaust Hose, Small Baskets (100), Large Baskets (100), Basket Lids (100), 2 Sample Record Note Pads, Spare Fuses.
#Lynx cu art cam Pc

24 reagent vials for EM processing, each 25 ml volume.12 reagent vials for HP processing, each 125 ml volume.Once the unit is properly configured for EM or HP processing, the operator loads the reagent carousel and the samples, selects the desired program and starts the run.Īt the end of the run, the sample is retained in the last reagent until the operator removes the sample. In addition to the proper program number selection, it is the responsibility of the end user to use the proper carousel positions and the appropriate type of reagent vials based on the selection of EM vs. Programs 1 through 10 are used for EM processing and programs 11-20 are used for HP processing. The operator may select the processing for EM or HP by the program numbers.

Once the programmed time in a given reagent is over, the sample is raised and the next reagent is rotated in the processing station. Based on the selection of agitation and vacuum, the LYNX II periodically moves the sample arm to provide agitation and applies vacuum when the agitation is not in progress.

At the processing station the sample is lowered in the reagent.

Based on the selected program by the user, the LYNX II rotates the reagent carousel until the selected reagent station is at the processing station. Tissues of either type are processed in the same manner: Samples are mounted on the sample arm and reagents are loaded on the reagent carousel. The tissues may be processed for EM or HP. LYNX II is a batch mode, tissue processing system.